Televes Televes
Televes
Language: en | es
Televes
Televes
Televes
Televes

FAQ 126-2002-en

I have ref. 5079: why doesn´t the symbol rate work from 2-45 mBaud?

There are some frequencies which have a symbol rate that is below 10 mBaud.

Respuesta: 

The QPSK/PAL ref. 5079 officially works from 10-30 mBaud.

Since rates below 10 mBaud could cause problems in some networks around the world, here at Televes we wanted to make sure that the unit worked properly everywhere.

Because of this, the technical specifications of this device state that the unit works from 10 to 30 mBaud.

However, as some networks can still work below this rate, the unit can be programmed (by the universal programmer ref. 7234) to a minimum of 5 mBaud

Therefore, the unit really works from 5-30 mBaud. Below these figures we cannot guarantee that it will work correctly.