Highlights
- S/FTP Foiled FTP Cable (foiled pairs)
- Solid copper inner conductor (23AWG)
- Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
Main features
- PE (Polyethylene) copper conductor insulation, 0.95mm diameter
- Aluminium+polyester shielding foil
- Tinned copper outer shielding braid
- LSFH (Low Smoke Free of Halogen) outer sheath, 0.70mm thick and 7.7mm diameter
- 79% nominal speed
Discover
Category 7A
Data cable category Cat 7A complies with the standard for 10 Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 6A/6/5e and Cat 7). Category 7A evolves over category 7, allowing to achieve transmission frequencies of up to 1000 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.
Our category 7A cables are characterized:
- Comply with: EN 50173-1:2011, ISO/IEC 11801-1:2017, IEC 61156-5:2009, EN 50288-4-1:2013, EN 50288-4-2:2013
- Transfer rate up to 10Gbps
- Frequency range of up to 1500 MHz (higher than the 1000 MHz specified by the standard)
- Nominal impedance of 100 ohms
- Maximum resistance per conductor below 93,8 ohms/Km
The RJ45 is a connector commonly used in structured cable networks. With up to 8 connection pins, it is adequate both for data networks (8 pairs), as well as telephone networks (2 pairs). It is usually used in networks compliant with standards TIA/EIA-568-B.
Type | | S/FTP |
---|
Euroclass | | Dca |
---|
Euroclass: Smoke Production | | s1a |
---|
Euroclass: Flaming droplets | | d2 |
---|
Euroclass: Acidity | | a1 |
---|
Categorie | | Cat 7A |
---|
Transmission bandwidth | | 1500MHz |
---|
Transfer rate | | 10Gbps |
---|
Conductor Diameter | mm | 0.58 |
---|
Conductor Material | | Solid copper |
---|
Conductor type AWG | | 23 |
---|
Copper weight | kg/km | 20 |
---|
Conductor isolation Diameter | mm | 1.43 |
---|
Conductor isolation Material | | Polyethylene |
---|
Crucifix filler | | No |
---|
Shielding foil of pairs | | Aluminium + Polyester |
---|
Outer shielding braid | | Tinned copper (CuSn) |
---|
Outer sheath Diameter | mm | 7.7 |
---|
Outer sheath Material | | LSFH |
---|
Outer sheath Thickness | mm | 0.7 |
---|
Rip cord | | No |
---|
Spark Test | Vac | 3000 |
---|
Nominal impedance | Ω | 100 |
---|
Conductor resistance | Ω/km | < 93.8 |
---|
Nominal speed | % | 79 |
---|
Operating temperature | °C | -25 ... 70 |
---|
Frequencies | | 1 MHz | 4 MHz | 8 MHz | 10 MHz | 16 MHz | 20 MHz | 25 MHz | 31.25 MHz | 62.5 MHz | 100 MHz | 200 MHz | 250 MHz | 300 MHz | 400 MHz | 500 MHz | 600 MHz | 800 MHz | 1000 MHz | 1200 MHz | 1500 MHz |
|
---|
Attenuation (max.) | dB/100m | 4 | -- | 4.9 | -- | 8 | -- | -- | -- | -- | 20.3 | -- | 32.5 | -- | -- | 46.7 | 51.4 | -- | 67.6 | -- | -- |
|
---|
Attenuation (typ.) | dB/100m | 2 | 3.5 | -- | 5.4 | 6.9 | 7.7 | 8.7 | 9.8 | 14.1 | 17.9 | 25.6 | 28.7 | 31.5 | 37.2 | 42 | 46.4 | 54.1 | 60.7 | 69.7 | 75.4 |
|
---|
NEXT (min.) | dB/100m | 65 | -- | -- | -- | 65 | -- | -- | -- | -- | 65 | -- | 59.1 | -- | -- | 53.6 | 52.1 | -- | 47.9 | -- | -- |
|
---|
NEXT (typ.) | dB/100m | 83.1 | 90.2 | 89.7 | 90.5 | 90.8 | 91.2 | 88.6 | 87.1 | 82.7 | 78.2 | 72.5 | 71.1 | 69.1 | 67.6 | 66.3 | 65 | 63.6 | 60.8 | 59.7 | 55.4 |
|
---|
PS NEXT (min.) | dB/100m | 62 | -- | -- | -- | 62 | -- | -- | -- | -- | 62 | -- | 56.1 | -- | -- | 50.6 | 49.1 | -- | 44.9 | -- | -- |
|
---|
PS NEXT (typ.) | dB/100m | 81.8 | 87.7 | 87 | 87.4 | 87.9 | 88.1 | 86.2 | 85.3 | 80.4 | 76 | 70 | 68.8 | 67.3 | 66.1 | 64.4 | 63 | 62.5 | 58.7 | 58 | 55 |
|
---|
ACR-N (min.) | dB/100m | 61 | -- | -- | -- | 57 | -- | -- | -- | -- | 44.7 | -- | 26.7 | -- | -- | 6.9 | 0.7 | -- | -19.6 | -- | -- |
|
---|
ACR-N (typ.) | dB/100m | 81.1 | 86.7 | 84.8 | 85 | 83.9 | 83.5 | 79.8 | 77.2 | 68.5 | 60.1 | 46.6 | 42 | 37.2 | 30.5 | 24.4 | 18.7 | 9.7 | -0.1 | -5 | -15 |
|
---|
PS ACR-N (min.) | dB/100m | 58 | -- | -- | -- | 54 | -- | -- | -- | -- | 41.7 | -- | 23.7 | -- | -- | 3.9 | -2.3 | -- | -22.6 | -- | -- |
|
---|
PS ACR-N (typ.) | dB/100m | 79.9 | 84.2 | 82.1 | 82 | 81 | 80.4 | 77.4 | 76.3 | 66.1 | 57.9 | 44.2 | 39.7 | 35.3 | 28.9 | 22.6 | 16.6 | 8.5 | -2.1 | -6.9 | -15.8 |
|
---|
ACR-F (min.) | dB/100m | 65 | -- | -- | -- | 63 | -- | -- | -- | -- | 47.4 | -- | 39.4 | -- | -- | 33.4 | 31.8 | -- | 27.4 | -- | -- |
|
---|
ACR-F (typ.) | dB/100m | 81.5 | 85.3 | 88.2 | 88.4 | 84.7 | 82.5 | 82 | 79.9 | 77 | 74.2 | 66.2 | 66.5 | 63.7 | 57.7 | 50.7 | 55 | 48.7 | 39.9 | 21.5 | 18 |
|
---|
PS ACR-F (min.) | dB/100m | 62 | -- | -- | -- | 60.3 | -- | -- | -- | -- | 44.4 | -- | 36.4 | -- | -- | 30.4 | 28.8 | -- | 24.4 | -- | -- |
|
---|
PS ACR-F (typ.) | dB/100m | 78.4 | 83 | 85.1 | 85.7 | 81.9 | 81 | 79.9 | 78.2 | 75.5 | 73 | 64.9 | 64.3 | 62 | 56.4 | 50.4 | 53.5 | 47.1 | 37.6 | 18.9 | 14 |
|
---|
Return losses (min.) | dB | 21 | -- | -- | -- | 20 | -- | -- | -- | -- | 14 | -- | 10 | -- | -- | 10 | -- | -- | 8 | -- | -- |
|
---|
Return losses (typ.) | dB | 26 | 28.7 | 30.1 | 31.6 | 33.3 | 32.9 | 31.7 | 36.5 | 33.5 | 33.2 | 27.8 | 25.7 | 24.9 | 23 | 20.3 | 19.3 | 17.7 | 16.2 | 14 | 13 |
|
---|
Mounting details
DETAIL VIEW OF THE DATA CABLE SECTION
- Inner conductor
- Inner conductor isolation
- Shielding foil
- Outer shielding braid
- Outer sheath