Highlights
- S/FTP Foiled FTP Cable (foiled pairs)
- Solid copper inner conductor (23AWG)
- Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
- PE (Polyethylene) copper conductor insulation, 1.30mm diameter
- Aluminium+polyester shielding foil
- Tinned copper outer shielding braid
- LSFH (Low Smoke Free of Halogen) outer sheath, 0.70mm thick and 7.4mm diameter
- 79% nominal speed
Discover
Category 7
Data cable category Cat 7 complies with the standard for 10 Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 6A/6/5e and Cat 3). Category 7 evolves over category 6A, allowing to achieve transmission frequencies of up to 600 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.
Our category 7 cables are characterized for:
- Comply with: EN 50173-1:2011, ISO/IEC 11801-1:2017, IEC 61156-5:2009, EN 50288-4-1:2013, EN 50288-4-2:2013
- Transfer rate up to 10Gbps
- Frequency range of up to 1000 MHz (higher than the 600 MHz specified by the standard)
- Nominal impedance of 100 ohms
- Maximum resistance per conductor below 93,8 ohms/Km
Compatibility of RJ45 connectors with Televes data cables:
Reference |
219602 |
219701 |
219910 |
212201 |
2123 |
212302 |
212305 |
212310 |
212101 |
219302 |
219312 |
219322 |
219102 |
212330 |
Female connectors |
209901/209907 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209905 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209921/209925 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
OK |
X |
X |
OK |
209903 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
X |
X |
X |
X |
OK* |
209923 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK |
OK* |
OK |
** |
OK* |
209501 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK |
OK* |
OK |
** |
OK* |
Male connectors
|
209902 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209961/209962 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209904 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
X |
X |
X |
X |
OK* |
209906 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209965/209966 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209922 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
X |
X |
OK |
X |
X |
OK* |
209924 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK* |
OK |
** |
OK* |
OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility
Model | | DK7000 |
---|
Type | | S/FTP |
---|
Euroclass | | Cca |
---|
Euroclass: Smoke Production | | s1a |
---|
Euroclass: Flaming droplets | | d1 |
---|
Euroclass: Acidity | | a1 |
---|
Categorie | | Cat 7 |
---|
Transmission bandwidth | | 1000MHz |
---|
Transfer rate | | 10Gbps |
---|
Conductor Diameter | mm | 0.55 |
---|
Conductor Material | | Solid copper |
---|
Conductor type AWG | | 23 |
---|
Copper weight | kg/km | 18.35 |
---|
Conductor isolation Diameter | mm | 1.3 |
---|
Conductor isolation Material | | Polyethylene |
---|
Crucifix filler | | No |
---|
Shielding foil of pairs | | Aluminium + Polyester |
---|
Outer shielding braid | | Tinned copper (CuSn) |
---|
Outer sheath Diameter | mm | 7.4 |
---|
Outer sheath Material | | LSFH |
---|
Outer sheath Thickness | mm | 0.7 |
---|
Rip cord | | No |
---|
Spark Test | Vac | 3000 |
---|
Nominal impedance | Ω | 100 |
---|
Conductor resistance | Ω/100m | < 9.38 |
---|
Nominal speed | % | 79 |
---|
Operating temperature | °C | -25 ... 70 |
---|
Frequencies | | 1 MHz | 4 MHz | 8 MHz | 10 MHz | 16 MHz | 20 MHz | 25 MHz | 31.25 MHz | 62.5 MHz | 100 MHz | 200 MHz | 250 MHz | 300 MHz | 400 MHz | 500 MHz | 600 MHz | 800 MHz | 1000 MHz |
|
---|
Attenuation (max.) | dB/100m | 4 | -- | -- | -- | 8.1 | -- | -- | -- | -- | 20.8 | -- | 33.8 | -- | -- | 49.3 | 54.6 | -- | -- |
|
---|
Attenuation (typ.) | dB/100m | 2 | 3.8 | 5.1 | 5.7 | 7.3 | 8.2 | 9.2 | 10.4 | 14.9 | 18.9 | 27 | 30.3 | 33.3 | 38.6 | 43.5 | 48.1 | 59.6 | 63.9 |
|
---|
NEXT (min.) | dB/100m | 65 | -- | -- | -- | 65 | -- | -- | -- | -- | 62.9 | -- | 56.9 | -- | -- | 52.4 | 51.2 | -- | -- |
|
---|
NEXT (typ.) | dB/100m | 85.7 | 92.2 | 90.6 | 93.9 | 90.1 | 92.1 | 87.8 | 86.3 | 81.2 | 77.8 | 71.1 | 69.3 | 68.9 | 66.7 | 64.9 | 62.5 | 62.6 | 58.6 |
|
---|
PS NEXT (min.) | dB/100m | 62 | -- | -- | -- | 62 | -- | -- | -- | -- | 59.9 | -- | 53.9 | -- | -- | 49.4 | 48.2 | -- | -- |
|
---|
PS NEXT (typ.) | dB/100m | 84.2 | 89.1 | 87.9 | 91.5 | 88 | 89.5 | 86.8 | 84.8 | 80.4 | 77.2 | 69.9 | 68.4 | 68.1 | 65.8 | 64.5 | 62.1 | 59.8 | 58.5 |
|
---|
ACR-N (min.) | dB/100m | 61 | -- | -- | -- | 56.9 | -- | -- | -- | -- | 42.1 | -- | 23.1 | -- | -- | 3.1 | -3.4 | -- | -- |
|
---|
ACR-N (typ.) | dB/100m | 83.6 | 88.4 | 85.4 | 88.1 | 82.8 | 83.9 | 78.5 | 75.8 | 66.1 | 58.7 | 43.8 | 38.6 | 35.2 | 27.5 | 20.8 | 14 | 3 | -5.2 |
|
---|
PS ACR-N (min.) | dB/100m | 58 | -- | -- | -- | 53.9 | -- | -- | -- | -- | 39.1 | -- | 20.1 | -- | -- | 0.1 | -6.4 | -- | -- |
|
---|
PS ACR-N (typ.) | dB/100m | 82.2 | 85.3 | 82.8 | 85.8 | 80.7 | 81.2 | 77.5 | 74.3 | 65.3 | 58.1 | 42.6 | 37.7 | 34.4 | 26.7 | 20.3 | 13.5 | 0.2 | -5.4 |
|
---|
ACR-F (min.) | dB/100m | 65 | -- | -- | -- | 57.5 | -- | -- | -- | -- | 44.4 | -- | 37.8 | -- | -- | 32.6 | 31.3 | -- | -- |
|
---|
ACR-F (typ.) | dB/100m | 83 | 86.9 | 87.6 | 87.7 | 84.7 | 83.3 | 83 | 81.1 | 78.2 | 74.8 | 65.2 | 63 | 66.3 | 59.5 | 54.1 | 53.8 | 42.8 | 34.6 |
|
---|
PS ACR-F (min.) | dB/100m | 62 | -- | -- | -- | 54.5 | -- | -- | -- | -- | 41.4 | -- | 34.8 | -- | -- | 29.6 | 28.3 | -- | -- |
|
---|
PS ACR-F (typ.) | dB/100m | 82 | 85 | 86.3 | 86.1 | 83.5 | 81.8 | 81.2 | 79 | 75.9 | 73.3 | 64.6 | 61.8 | 64 | 57.5 | 52.7 | 51.4 | 41 | 32.3 |
|
---|
Return losses (min.) | dB | 21 | -- | -- | -- | 20 | -- | -- | -- | -- | 14 | -- | 10 | -- | -- | 10 | 10 | -- | -- |
|
---|
Return losses | dB | 25.5 | 28.5 | 30.7 | 32 | 33.1 | 36.9 | 33.1 | 34.1 | 34.6 | 33 | 29.7 | 28.5 | 26.9 | 24.9 | 22.2 | 21.7 | 18.4 | 14.9 |
|
---|
Mounting details
DETAIL VIEW OF THE DATA CABLE SECTION
- Inner conductor
- Inner conductor isolation
- Shielding foil
- Outer shielding braid
- Outer sheath