The wishlist name can't be left blank

DK5000E data cable U/UTP Cat 5E Fca PE 24AWG

Category-5E and Fca Euroclass data cable, U/UTP type (Unfoiled), with copper conductor and PE sheath, black colour (RAL 9005).
Ref. 219701
Product Sheet
EAN13: 8424450169568
SKU
219701
Highlights
  • U/UTP data Cable
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • PE (Polyethylene) outer sheath
  • Certified according to the applicable standards as defined in the available declarations of conformity and performance

Discover

Category 5E

The data cable category Cat 5E (enhanced or improved) originates from the Cat 5 and it is backwards compatible, with the standards of the inferior categories (Cat 5 and Cat 3). The 5E category achieves transmission frequencies of up to 100 MHz (in each pair) with a throughput of 100Mbps. This type of cable complies with the standards 10BASE-T and 100BASE-T and will be mainly used in these installations.

They are characterized for:

  • Comply with TIA/EIA-568B.2-1
  • Transfer rate up to 100Mbps
  • Frequency range of up to 100MHz
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 Ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

What is the PoE technology?

PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
The latter defines two additional types (Type 3 and Type 4) whit higher power levels, making four PoE levels in total.

The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Powr Sourcing Equipments) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
  • Standards PoE Type Maximum PSE Power Power for the PD Nº of Twisted Pairs Used
    IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
    IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
    IEEE 802.3bt Type 3 PoE++
    4PPoE
    60W 51W 4
    Type 4 90-100W 71W 4

    Recommended uses according to PoE type:

  • Type 1: IP phones, basic IP camaras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion camaras (PTZ), IP video phones, alarm systemns.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ camaras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.

  • Devices that support a certain type of PoE can also be powered by a higher type, offering greater versatility and scalability in installations.

    Main advantages of PoE technology in installations:

  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.

  • ModelDK5000E
    TypeU/UTP
    EuroclassFca
    CategorieCat 5E
    Transmission bandwidth100MHz
    Transfer rate100Mbps
    Conductor Diametermm0.5
    Conductor MaterialElectrolytic copper
    Conductor type AWG24
    Conductor isolation Diametermm0.95
    Conductor isolation MaterialPolyethylene
    Crucifix fillerNo
    Outer sheath Diametermm5.5
    Outer sheath MaterialPE
    Outer sheath Thicknessmm0.6
    Rip cordYes
    Spark TestVac3000
    Nominal impedanceΩ100
    Conductor resistanceOhm/100m < 9.38
    Nominal speed%69
    Working voltageV300
    Operating temperature°C -40 ... 80
    Frequencies
    1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz
    Attenuation (max.)dB/100m
    2 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17 22
    NEXT (min.)dB/100m
    65.3 56.3 51.8 50.3 47.2 45.8 44.3 42.9 38.4 35.3
    PS NEXT (min.)dB/100m
    62.3 53.3 48.8 47.3 44.2 42.8 41.3 39.9 35.4 32.3
    ACR-N (min.)dB/100m
    63.3 52.2 46 43.8 39 36.5 33.9 31.2 21.4 13.3
    PS ACR-N (min.)dB/100m
    60.3 49.2 43 40.8 36 33.5 30.9 28.2 18.4 10.3
    ACR-F (min.)dB/100m
    63.8 51.8 45.7 43.8 39.7 37.8 35.8 33.9 27.9 23.8
    PS ACR-F (min.)dB/100m
    60.8 48.8 42.7 40.8 36.7 34.8 32.8 30.9 24.9 20.8
    Return losses (min.)dB
    20 23 24.5 25 25 25 24.3 23.6 21.5 20.1

    Physical data

    Net weight: 26 g

    Gross weight: 26 g

    Width: 7 mm

    Height: 1,000 mm

    Depth: 7 mm

    Main product weight: 23 g

    Packing

    Box 305 m

    Pallet 13725 m

    More Information
    tlv_tags

    Category 5E

    The data cable category Cat 5E (enhanced or improved) originates from the Cat 5 and it is backwards compatible, with the standards of the inferior categories (Cat 5 and Cat 3). The 5E category achieves transmission frequencies of up to 100 MHz (in each pair) with a throughput of 100Mbps. This type of cable complies with the standards 10BASE-T and 100BASE-T and will be mainly used in these installations.

    They are characterized for:

    • Comply with TIA/EIA-568B.2-1
    • Transfer rate up to 100Mbps
    • Frequency range of up to 100MHz
    • Includes rip cord to make it easier to strip the cable
    • Nominal impedance of 100 ohms
    • Maximum resistance per conductor below 9.38 Ohms/100m

    Compatibility of RJ45 connectors with Televes data cables:

    Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
    Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
    209905 OK OK OK OK OK OK OK OK OK X X X X X
    209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
    209926 OK OK OK OK OK OK OK OK OK X X OK OK X
    209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
    209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
    209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
    Male connectors
    209902 OK OK OK OK OK OK OK OK OK X X X X X
    209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
    209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
    209906 OK OK OK OK OK OK OK OK OK X X X X X
    209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
    209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
    209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

    OK Compatible
    OK* Compatible, but there are better choices
    X Incompatible
    ** Mechanical compatibility

    What is the PoE technology?

    PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
    The latter defines two additional types (Type 3 and Type 4) whit higher power levels, making four PoE levels in total.

    The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Powr Sourcing Equipments) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
  • Standards PoE Type Maximum PSE Power Power for the PD Nº of Twisted Pairs Used
    IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
    IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
    IEEE 802.3bt Type 3 PoE++
    4PPoE
    60W 51W 4
    Type 4 90-100W 71W 4

    Recommended uses according to PoE type:

  • Type 1: IP phones, basic IP camaras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion camaras (PTZ), IP video phones, alarm systemns.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ camaras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.

  • Devices that support a certain type of PoE can also be powered by a higher type, offering greater versatility and scalability in installations.

    Main advantages of PoE technology in installations:

  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.
  • tlv_caracteristicas_ficha

    El cable de datos de tipo Cat-5E (enhanced o mejorado) tiene su origen sobre el Cat-5 y es compatible hacia atrás, con los estándares de categorías inferiores (Cat-5 y Cat-3). La categoría 5E alcanza frecuencias de transmisión de hasta 100 MHz (en cada par) con una velocidad de 100Mbps de transferencia. Este tipo de cable de datos cumple el estándar 10BASE-T y 100BASE-T, utilizándose principalmente para estas instalaciones.

    Se caracterizan por:

    • Conductor central cobre sólido (24AWG)
    • Diámetro externo del cable 5,5mm
    • Posee hilo de rasgado para su fácil apertura
    • Acorde norma EN50173PL Class D-2002 para 90 metros
    • Impedancia nominal de 100 ohmios
    • Resistencia máxima por conductor, menor a 117 ohmios/Km
    tlv_reflog CAT5PE305B
    tlv_tabla_especificaciones
    ModelDK5000E
    TypeU/UTP
    EuroclassFca
    CategorieCat 5E
    Transmission bandwidth100MHz
    Transfer rate100Mbps
    Conductor Diametermm0.5
    Conductor MaterialElectrolytic copper
    Conductor type AWG24
    Conductor isolation Diametermm0.95
    Conductor isolation MaterialPolyethylene
    Crucifix fillerNo
    Outer sheath Diametermm5.5
    Outer sheath MaterialPE
    Outer sheath Thicknessmm0.6
    Rip cordYes
    Spark TestVac3000
    Nominal impedanceΩ100
    Conductor resistanceOhm/100m < 9.38
    Nominal speed%69
    Working voltageV300
    Operating temperature°C -40 ... 80
    Frequencies
    1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz
    Attenuation (max.)dB/100m
    2 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17 22
    NEXT (min.)dB/100m
    65.3 56.3 51.8 50.3 47.2 45.8 44.3 42.9 38.4 35.3
    PS NEXT (min.)dB/100m
    62.3 53.3 48.8 47.3 44.2 42.8 41.3 39.9 35.4 32.3
    ACR-N (min.)dB/100m
    63.3 52.2 46 43.8 39 36.5 33.9 31.2 21.4 13.3
    PS ACR-N (min.)dB/100m
    60.3 49.2 43 40.8 36 33.5 30.9 28.2 18.4 10.3
    ACR-F (min.)dB/100m
    63.8 51.8 45.7 43.8 39.7 37.8 35.8 33.9 27.9 23.8
    PS ACR-F (min.)dB/100m
    60.8 48.8 42.7 40.8 36.7 34.8 32.8 30.9 24.9 20.8
    Return losses (min.)dB
    20 23 24.5 25 25 25 24.3 23.6 21.5 20.1
    tlv_ean 8424450169568
    tlv_dim_product_x 7
    tlv_dim_product_x_label Width
    tlv_dim_product_x_unit mm
    tlv_dim_product_y 1,000
    tlv_dim_product_y_label Height
    tlv_dim_product_y_unit mm
    tlv_dim_product_z 7
    tlv_dim_product_z_label Depth
    tlv_dim_product_z_unit mm
    tlv_weight_product_label Main product weight
    tlv_weight_product 23
    tlv_weight_product_unit g
    tlv_gross_weight_label Gross weight
    tlv_gross_weight 26
    tlv_gross_weight_unit g
    tlv_net_weight_label Net weight
    tlv_net_weight_unit g
    tlv_net_weight 26
    tlv_1_type_pack Box
    tlv_1_type_pcs_pack m
    tlv_1_pcs_pack 305
    tlv_2_pcs_pack 13725
    tlv_2_type_pack Pallet
    tlv_2_type_pcs_pack m

    Mounting details

    DETAIL VIEW OF THE DATA CABLE SECTION

    1. Inner conductor
    2. Inner conductor isolation
    3. Outer sheath
    4. Rip cord

    Comparison between two connectorisation techniques of a data cable with a female connector

    How to install a female RJ45 data connector using a professional tool

    How to install a female RJ45 data connector manually