Highlights
- F/UTP cable Foiled UTP Cable
- Solid copper inner conductor (23AWG)
- Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
Main features
- PE (Polyethylene) copper conductor insulation, 0.95mm diameter
- Aluminium foil + polyester between foil and outer cable sheath
- CuSn ground cable (0.4mm)
- LSFH (Low Smoke Free of Halogen) outer sheath, 0.60mm thick and 7.2mm diameter
- 72% nominal speed
Discover
Category 6
Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.
Our category 6 cables are characterized:
- Comply with TIA/EIA-568B.2-1
- Crucifix type padding
- Transfer rate up to 1Gbps
- Frequency range of up to 250 MHz and up to 400MHz in some references
- Includes rip cord to make it easier to strip the cable
- Nominal impedance of 100 ohms
- Maximum resistance per conductor below 9.38 ohms/100m
Compatibility of RJ45 connectors with Televes data cables:
Reference |
219602 |
219701 |
219910 |
212201 |
2123 |
212302 |
212305 |
212310 |
212101 |
219302 |
219312 |
219322 |
219102 |
212330 |
Female connectors |
209901/209907 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209905 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209921/209925 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
OK |
X |
X |
OK |
209903 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
X |
X |
X |
X |
OK* |
209923 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK |
OK* |
OK |
** |
OK* |
209501 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK |
OK* |
OK |
** |
OK* |
Male connectors
|
209902 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209961/209962 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209904 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
X |
X |
X |
X |
OK* |
209906 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209965/209966 |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
OK |
X |
X |
X |
X |
X |
OK |
209922 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
X |
X |
OK |
X |
X |
OK* |
209924 |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK* |
OK |
OK* |
OK |
** |
OK* |
OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility
Type | | F/UTP |
---|
Euroclass | | Dca |
---|
Euroclass: Smoke Production | | s2 |
---|
Euroclass: Flaming droplets | | d2 |
---|
Euroclass: Acidity | | a1 |
---|
Categorie | | Cat 6 |
---|
Transmission bandwidth | | 250MHz |
---|
Transfer rate | | 1Gbps |
---|
Conductor Diameter | mm | 0.55 |
---|
Conductor Material | | Solid copper |
---|
Conductor type AWG | | 23 |
---|
Conductor isolation Diameter | mm | 1.14 |
---|
Conductor isolation Material | | Polyethylene |
---|
Crucifix filler | | Yes |
---|
Shielding foil of pairs | | Aluminium + Polyester |
---|
Outer sheath Diameter | mm | 7.2 |
---|
Outer sheath Material | | LSFH |
---|
Outer sheath Thickness | mm | 0.6 |
---|
Rip cord | | Yes |
---|
Spark Test | Vac | 3000 |
---|
Nominal impedance | Ω | 100 |
---|
Conductor resistance | Ω/100m | < 9.38 |
---|
Nominal speed | % | 72 |
---|
Operating temperature | °C | -25 ... 70 |
---|
Frequencies | | 1 MHz | 4 MHz | 8 MHz | 10 MHz | 16 MHz | 20 MHz | 25 MHz | 31.25 MHz | 62.5 MHz | 100 MHz | 200 MHz | 250 MHz |
|
---|
Attenuation (max.) | dB/100m | 2 | 3.8 | 5.3 | 6 | 7.6 | 8.5 | 9.5 | 10.7 | 15.4 | 19.8 | 29 | 32.8 |
|
---|
Attenuation (typ.) | dB/100m | 2 | 3.7 | 5.2 | 5.8 | 7.3 | 8.2 | 9.2 | 10.3 | 14.6 | 18.6 | 26.5 | 29.8 |
|
---|
NEXT (min.) | dB/100m | 74.3 | 65.3 | 60.8 | 59.3 | 56.2 | 54.8 | 53.3 | 51.9 | 47.4 | 44.3 | 39.8 | 38.3 |
|
---|
NEXT (typ.) | dB/100m | 88.9 | 78.7 | 77.7 | 71.7 | 69.3 | 71.1 | 65.8 | 63.9 | 58.6 | 54 | 48.7 | 45.8 |
|
---|
PS NEXT (min.) | dB/100m | 72.3 | 63.3 | 58.8 | 57.3 | 54.2 | 52.8 | 51.3 | 49.9 | 45.4 | 42.3 | 37.8 | 36.3 |
|
---|
PS NEXT (typ.) | dB/100m | 86.7 | 76.3 | 75 | 69.8 | 67.2 | 69 | 63.7 | 61.4 | 56.5 | 52.8 | 46 | 42.6 |
|
---|
ACR-N (min.) | dB/100m | 72.3 | 61.5 | 55.5 | 53.3 | 48.6 | 46.3 | 43.8 | 41.2 | 32 | 24.5 | 10.8 | 5.5 |
|
---|
ACR-N (typ.) | dB/100m | 87 | 75.1 | 72.7 | 66.2 | 62 | 62.9 | 56.7 | 53.8 | 44.1 | 35.4 | 22.2 | 16 |
|
---|
PS ACR-N (min.) | dB/100m | 70.3 | 59.5 | 53.5 | 51.3 | 46.6 | 44.3 | 41.8 | 39.2 | 30 | 22.5 | 8.8 | 3.5 |
|
---|
PS ACR-N (typ.) | dB/100m | 84.7 | 72.7 | 70.1 | 64.2 | 60 | 60.9 | 54.6 | 51.2 | 42 | 34.3 | 19.6 | 13 |
|
---|
ACR-F (min.) | dB/100m | 67.8 | 55.8 | 49.7 | 47.8 | 43.7 | 41.8 | 39.8 | 37.9 | 31.9 | 27.8 | 21.8 | 19.8 |
|
---|
ACR-F (typ.) | dB/100m | 81 | 70.4 | 67.2 | 66.9 | 63.7 | 59 | 55.1 | 53.5 | 49.3 | 43.9 | 40.5 | 35.9 |
|
---|
PS ACR-F (min.) | dB/100m | 64.8 | 52.8 | 46.7 | 44.8 | 40.7 | 38.8 | 36.8 | 34.9 | 28.9 | 24.8 | 18.8 | 16.8 |
|
---|
PS ACR-F (typ.) | dB/100m | 79.2 | 67.8 | 63.8 | 63.2 | 61.6 | 57 | 52.9 | 50.5 | 46 | 43.5 | 37.5 | 34.8 |
|
---|
Return losses (min.) | dB | 20 | 23 | 24.5 | 25 | 25 | 25 | 24.3 | 23.6 | 21.5 | 20.1 | 18 | 17.3 |
|
---|
Return losses (typ.) | dB | 26.8 | 28.5 | 35.1 | 36.2 | 41.8 | 39.9 | 40.3 | 39.4 | 35.2 | 32 | 32.2 | 30.1 |
|
---|
Mounting details
DETAIL VIEW OF THE DATA CABLE SECTION
- Inner conductor
- Inner conductor isolation
- Crucifix Filler
- Outer sheath
- Rip cord
- Shielding foil
- Drain wire