The wishlist name can't be left blank
Ethernet Patch Cord U/UTP Cat 6 LSFH, blue

Ethernet Patch Cord U/UTP Cat 6 LSFH, blue

Ethernet Patch Cord U/UTP Cat 6 LSFH, white

Preconnected Ethernet patch cord with RJ45 connector at each end. It is made of a Category-6 data cable, U/UTP type, with a flexible copper inner conductor 24 AWG and outer sheath made of white LSFH (Low Smoke Free of Halogen).
In stock
SKU
2090xx_latiguillos_cat6_LSFH_blanco
Select your product
Grouped product items
Ref. 209011 Packing: Box, Length: 0.5 m
Ref. 209012 Packing: Box, Length: 1 m
Ref. 209013 Packing: Box, Length: 2 m
Ref. 209014 Packing: Box, Length: 3 m
Ref. 209301 Packing: Bag, Length: 0.3 m
Product Sheet
Highlights
  • U/UTP data Cable
  • Flexible copper inner conductor (24AWG)
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • LSFH (Low Smoke Free Of Halogen) outer sheath
  • 72% nominal speed
  • RJ45 connectors with gold plated connector ends

Discover

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

The RJ45 is a connector commonly used in structured cable networks. With up to 8 connection pins, it is adequate both for data networks (8 pairs), as well as telephone networks (2 pairs). It is usually used in networks compliant with standards TIA/EIA-568-B.

What is the PoE technology?

PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
The latter defines two additional types (Type 3 and Type 4) with higher power levels, making four PoE levels in total.
The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Power Sourcing Equipment) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
Standard Type of PoE Maximum PSE Power Power for the PD No. of Pairs Used
IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
IEEE 802.3bt Type 3 PoE++
4PPoE
60W 51W 4
Type 4 90-100W 71W 4
Recommended uses according to PoE type:
  • Type 1: IP phones, basic IP cameras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion cameras (PTZ), IP video phones, alarm systems.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ cameras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.
Devices compatible with a specific type of PoE can also be powered using a higher type, which provides greater versatility and scalability in installations.
The recommended data cables and connectors for Types 3 and 4 are CAT6A and above with shielding. This recommendation is based on their better ability to dissipate the heat generated during the transmission of electrical power.
CAT6A UTP cables and connectors are technically compatible with PoE++ technology, but they may present limitations over distances greater than 55 m. Since they lack shielding, thermal dissipation is less efficient, which can cause voltage drops along the run and affect the proper operation of the powered device. This also happens with CAT5e and CAT6; they are compatible with PoE++ but not recommended for distances over 55 m.
Main advantages of PoE technology in installations:
  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.

Ref. 209011
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.008
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm0.5
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -22 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
65 63 58.2 56.6 53.2 51.6 50 48.4 43.4 39.9 34.8 33.1
PS NEXT (typ.)dB/100m
62 60.5 55.6 54 50.6 49 47.3 45.7 40.6 37.1 31.9 30.2
ACR-F (typ.)dB/100m
63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3
PS ACR-F (typ.)dB/100m
60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3
Return lossesdB
19 19 19 19 18 17.5 17 16.5 14 12 9 8

Physical data

Net weight: 27 g

Gross weight: 27 g

Width: 12 mm

Height: 505 mm

Depth: 10 mm

Main product weight: 27 g

Packing

Box 10 pcs.

Ref. 209012
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.008
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm1
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -22 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
65 63 58.2 56.6 53.2 51.6 50 48.4 43.4 39.9 34.8 33.1
PS NEXT (typ.)dB/100m
62 60.5 55.6 54 50.6 49 47.3 45.7 40.6 37.1 31.9 30.2
ACR-F (typ.)dB/100m
63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3
PS ACR-F (typ.)dB/100m
60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3
Return lossesdB
19 19 19 19 18 17.5 17 16.5 14 12 9 8

Physical data

Net weight: 44 g

Gross weight: 44 g

Width: 12 mm

Height: 1,010 mm

Depth: 10 mm

Packing

Box 10 pcs.

Ref. 209013
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.008
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm2
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -22 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
65 63 58.2 56.6 53.2 51.6 50 48.4 43.4 39.9 34.8 33.1
PS NEXT (typ.)dB/100m
62 60.5 55.6 54 50.6 49 47.3 45.7 40.6 37.1 31.9 30.2
ACR-F (typ.)dB/100m
63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3
PS ACR-F (typ.)dB/100m
60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3
Return lossesdB
19 19 19 19 18 17.5 17 16.5 14 12 9 8

Physical data

Net weight: 81 g

Gross weight: 81 g

Width: 12 mm

Height: 2,020 mm

Depth: 10 mm

Packing

Box 10 pcs.

Ref. 209014
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.008
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm3
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -22 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
65 63 58.2 56.6 53.2 51.6 50 48.4 43.4 39.9 34.8 33.1
PS NEXT (typ.)dB/100m
62 60.5 55.6 54 50.6 49 47.3 45.7 40.6 37.1 31.9 30.2
ACR-F (typ.)dB/100m
63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3
PS ACR-F (typ.)dB/100m
60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3
Return lossesdB
19 19 19 19 18 17.5 17 16.5 14 12 9 8

Physical data

Net weight: 116 g

Gross weight: 116 g

Width: 12 mm

Height: 3,010 mm

Depth: 10 mm

Packing

Box 10 pcs.

Ref. 209301
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.022
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm0.3
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -13 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
74.3 65.3 60.8 59.3 56.3 54.8 53.3 51.9 47.4 44.3 39.8 38.3
PS NEXT (typ.)dB/100m
72.3 63.3 58.8 57.3 54.3 52.8 51.3 49.9 45.4 42.3 37.8 36.3
ACR-F (typ.)dB/100m
67.8 55.7 49.7 47.8 43.7 41.7 39.8 37.9 31.8 27.8 21.7 19.8
PS ACR-F (typ.)dB/100m
64.8 52.7 46.7 44.8 40.7 38.7 36.8 34.9 28.8 24.8 18.7 16.8
Return lossesdB
--23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3

Physical data

Net weight: 16 g

Gross weight: 18 g

Width: 300 mm

Height: 15 mm

Depth: 11 mm

Main product weight: 16 g

Packing

Bag 1 pcs.

More Information
tlv_reflog_group_search PK6P05W,PK6P1W,PK6P2W,PK6P3W,PK6L03V-T
tlv_tags

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

The RJ45 is a connector commonly used in structured cable networks. With up to 8 connection pins, it is adequate both for data networks (8 pairs), as well as telephone networks (2 pairs). It is usually used in networks compliant with standards TIA/EIA-568-B.

What is the PoE technology?

PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
The latter defines two additional types (Type 3 and Type 4) with higher power levels, making four PoE levels in total.
The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Power Sourcing Equipment) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
Standard Type of PoE Maximum PSE Power Power for the PD No. of Pairs Used
IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
IEEE 802.3bt Type 3 PoE++
4PPoE
60W 51W 4
Type 4 90-100W 71W 4
Recommended uses according to PoE type:
  • Type 1: IP phones, basic IP cameras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion cameras (PTZ), IP video phones, alarm systems.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ cameras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.
Devices compatible with a specific type of PoE can also be powered using a higher type, which provides greater versatility and scalability in installations.
The recommended data cables and connectors for Types 3 and 4 are CAT6A and above with shielding. This recommendation is based on their better ability to dissipate the heat generated during the transmission of electrical power.
CAT6A UTP cables and connectors are technically compatible with PoE++ technology, but they may present limitations over distances greater than 55 m. Since they lack shielding, thermal dissipation is less efficient, which can cause voltage drops along the run and affect the proper operation of the powered device. This also happens with CAT5e and CAT6; they are compatible with PoE++ but not recommended for distances over 55 m.
Main advantages of PoE technology in installations:
  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.
tlv_tabla_especificaciones
TypeU/UTP
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.008
Conductor MaterialFlexible copper
Conductor type AWG24
Conductor isolation Diameterin0.038
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diameterin0.224
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordNo
Cable lengthm0.5
Data connector typeRJ45
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/km < 117
Nominal speed%72
Working voltageV300
Operating temperature°F -22 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31,25 MHz62,5 MHz100 MHz200 MHz250 MHz
NEXT (typ.)dB/100m
65 63 58.2 56.6 53.2 51.6 50 48.4 43.4 39.9 34.8 33.1
PS NEXT (typ.)dB/100m
62 60.5 55.6 54 50.6 49 47.3 45.7 40.6 37.1 31.9 30.2
ACR-F (typ.)dB/100m
63.3 51.2 45.2 43.3 39.2 37.2 35.3 33.4 27.3 23.3 17.2 15.3
PS ACR-F (typ.)dB/100m
60.3 48.2 42.2 40.3 36.2 34.2 32.3 30.4 24.3 20.3 14.2 12.3
Return lossesdB
19 19 19 19 18 17.5 17 16.5 14 12 9 8
tlv_sku_group_search 209011,209012,209013,209014,209301
tlv_diferencias Packing: Box, Length: 0.5 m
tlv_dim_product_x 12
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 505
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 10
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 27
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 27
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 27
tlv_1_type_pack Box
tlv_1_type_pcs_pack pcs.
tlv_1_pcs_pack 10