The wishlist name can't be left blank

DK6000 data cable F/UTP Cat 6 Dca LSFH 23AWG

Category-6 and Dca Euroclass data cable, F/UTP type (Foiled cable, Unfoiled pairs), with copper conductor and LSFH sheath (Low Smoke Free of Halogen), purple colour (RAL 4008).

Recommended for PoE and PoE++.

Ref. 212101
Product Sheet
EAN13: 8424450186510
SKU
212101
Highlights
  • F/UTP Cable
  • Solid copper inner conductor (23AWG)
  • Technically compatible with PoE/PoE+/PoE++ (Power over Ethernet) technology, allowing the cable to power network devices
  • Aluminium foil + polyester between foil and outer cable sheath
  • CuSn ground cable
  • LSFH (Low Smoke Free of Halogen) outer sheath
  • 72% nominal speed
  • Certified according to the applicable standards as defined in the available declarations of conformity and performance

Discover

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

What is the PoE technology?

PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
The latter defines two additional types (Type 3 and Type 4) with higher power levels, making four PoE levels in total.
The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Power Sourcing Equipment) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
Standard Type of PoE Maximum PSE Power Power for the PD No. of Pairs Used
IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
IEEE 802.3bt Type 3 PoE++
4PPoE
60W 51W 4
Type 4 90-100W 71W 4
Recommended uses according to PoE type:
  • Type 1: IP phones, basic IP cameras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion cameras (PTZ), IP video phones, alarm systems.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ cameras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.
Devices compatible with a specific type of PoE can also be powered using a higher type, which provides greater versatility and scalability in installations.
The recommended data cables and connectors for Types 3 and 4 are CAT6A and above with shielding. This recommendation is based on their better ability to dissipate the heat generated during the transmission of electrical power.
CAT6A UTP cables and connectors are technically compatible with PoE++ technology, but they may present limitations over distances greater than 55 m. Since they lack shielding, thermal dissipation is less efficient, which can cause voltage drops along the run and affect the proper operation of the powered device. This also happens with CAT5e and CAT6; they are compatible with PoE++ but not recommended for distances over 55 m.
Main advantages of PoE technology in installations:
  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.

ModelDK6000
TypeF/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diametermm1.14
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Shielding foil of pairsAluminium + Polyester
Outer sheath Diametermm7.2
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.6
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%72
Working voltageV300
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
2 3.7 5.2 5.8 7.3 8.2 9.2 10.3 14.6 18.6 26.5 29.8
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
88.9 78.7 77.7 71.7 69.3 71.1 65.8 63.9 58.6 54 48.7 45.8
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
86.7 76.3 75 69.8 67.2 69 63.7 61.4 56.5 52.8 46 42.6
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
87 75.1 72.7 66.2 62 62.9 56.7 53.8 44.1 35.4 22.2 16
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
84.7 72.7 70.1 64.2 60 60.9 54.6 51.2 42 34.3 19.6 13
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
81 70.4 67.2 66.9 63.7 59 55.1 53.5 49.3 43.9 40.5 35.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
79.2 67.8 63.8 63.2 61.6 57 52.9 50.5 46 43.5 37.5 34.8
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3
Return lossesdB
26.8 28.5 35.1 36.2 41.8 39.9 40.3 39.4 35.2 32 32.2 30.1

Physical data

Net weight: 54 g

Gross weight: 57 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 54 g

Packing

Reel 500 m

Pallet 13500 m

More Information
tlv_tags

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

What is the PoE technology?

PoE (Power over Ethernet) technology enables the simultaneous transmission of power and data over the same Ethernet network cable, eliminating the need for separate power supplies. Currently, there are three main standards: IEEE 802.3af (PoE), IEEE 802.3at (PoE+), and IEEE 802.3bt (PoE++/4PPoE).
The latter defines two additional types (Type 3 and Type 4) with higher power levels, making four PoE levels in total.
The three aspects that differentiate the different types of PoE are:

  • Maximum PSE (Power Sourcing Equipment) Power: Indicates the maximum amount of electrical power that can be supplied by an equipment over the Ethernet cable.
  • Power for the PD (Powered Device): This is the electrical power that can be received by the device powered by the cable.
  • Number of Twisted Pairs Used: Refers to how many twisted pairs in the Ethernet cable are used to deliver electrical power.
Standard Type of PoE Maximum PSE Power Power for the PD No. of Pairs Used
IEEE 802.3af Type 1 PoE 15.4W 12.95W 2
IEEE 802.3at Type 2 PoE+ 30W 25.5W 2
IEEE 802.3bt Type 3 PoE++
4PPoE
60W 51W 4
Type 4 90-100W 71W 4
Recommended uses according to PoE type:
  • Type 1: IP phones, basic IP cameras. low-demand Wi-Fi access points, sensors or simple IoT devices.
  • Type 2: Dual band Wi-Fi access points, IP motion cameras (PTZ), IP video phones, alarm systems.
  • Type 3: Wi-Fi 6 / Wi-Fi 6E access points, heated PTZ cameras, multimedia terminals, video conferencing equipment.
  • Type 4: Monitors or touch screens, desktops, high-performance network equipment.
Devices compatible with a specific type of PoE can also be powered using a higher type, which provides greater versatility and scalability in installations.
The recommended data cables and connectors for Types 3 and 4 are CAT6A and above with shielding. This recommendation is based on their better ability to dissipate the heat generated during the transmission of electrical power.
CAT6A UTP cables and connectors are technically compatible with PoE++ technology, but they may present limitations over distances greater than 55 m. Since they lack shielding, thermal dissipation is less efficient, which can cause voltage drops along the run and affect the proper operation of the powered device. This also happens with CAT5e and CAT6; they are compatible with PoE++ but not recommended for distances over 55 m.
Main advantages of PoE technology in installations:
  • Quick and cost-effective installation by using the same cable for power and data transmission.
  • Greater installation flexibility as there is no need to rely on auxiliary power sockets.
  • More efficient management and optimised maintenance thanks to the monitoring and administration of the power supply of all equipment from a single point.
  • Cost reduction by avoiding electrical conduits and external power supplies.
  • Increased safety by minimising electrical risks in the installation, thanks to the use of low voltage.
tlv_caracteristicas_ficha

Data cable category Cat-6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat-5/5e and Cat-3). Category 6 includes characteristics and specifications to avoid crosstalk and noise. Achieves transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

The main features of Televes’ Cat-6 cables are:

  • TIA/EIA568B.2-1 compliant
  • Crucifix type padding
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 117 ohms/Km
tlv_reflog CAT6L500V
tlv_tabla_especificaciones
ModelDK6000
TypeF/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diametermm1.14
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Shielding foil of pairsAluminium + Polyester
Outer sheath Diametermm7.2
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.6
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%72
Working voltageV300
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
2 3.7 5.2 5.8 7.3 8.2 9.2 10.3 14.6 18.6 26.5 29.8
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
88.9 78.7 77.7 71.7 69.3 71.1 65.8 63.9 58.6 54 48.7 45.8
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
86.7 76.3 75 69.8 67.2 69 63.7 61.4 56.5 52.8 46 42.6
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
87 75.1 72.7 66.2 62 62.9 56.7 53.8 44.1 35.4 22.2 16
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
84.7 72.7 70.1 64.2 60 60.9 54.6 51.2 42 34.3 19.6 13
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
81 70.4 67.2 66.9 63.7 59 55.1 53.5 49.3 43.9 40.5 35.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
79.2 67.8 63.8 63.2 61.6 57 52.9 50.5 46 43.5 37.5 34.8
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3
Return lossesdB
26.8 28.5 35.1 36.2 41.8 39.9 40.3 39.4 35.2 32 32.2 30.1
tlv_ean 8424450186510
tlv_dim_product_x 7
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 7
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 54
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 57
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 54
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 500
tlv_2_pcs_pack 13500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE DATA CABLE SECTION

  1. Inner conductor
  2. Inner conductor isolation
  3. Crucifix Filler
  4. Outer sheath
  5. Rip cord
  6. Shielding foil
  7. Drain wire