The wishlist name can't be left blank
DK6000 data cable U/UTP Cat 6 Fca PE 24AWG

DK6000 data cable U/UTP Cat 6 Fca PE 24AWG

DK6000 data cable U/UTP Cat 6 Dca LSFH 23AWG

DK6000 data cable U/UTP Cat 6 Dca LSFH 23AWG

DK6000 data cable F/UTP Cat 6 Dca LSFH 23AWG

Category-6 and Dca Euroclass data cable, F/UTP type (Foiled cable, Unfoiled pairs), with copper conductor and LSFH sheath (Low Smoke Free of Halogen), purple colour (RAL 4008).

Supplied in a 500m wood reel.

Ref. 212101
Product Sheet
EAN13: 8424450186510
SKU
212101
Highlights
  • F/UTP cable Foiled UTP Cable
  • Solid copper inner conductor (23AWG)
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • PE (Polyethylene) copper conductor insulation, 0.95mm diameter
  • Aluminium foil + polyester between foil and outer cable sheath
  • CuSn ground cable (0.4mm)
  • LSFH (Low Smoke Free of Halogen) outer sheath, 0.60mm thick and 7.2mm diameter
  • 72% nominal speed

Discover

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219910 212201   2123   212302 212305 212310 212101 219302 219312 219322 219102 212330
Female connectors 209901/209907 OK OK OK OK OK OK OK OK X X X X X OK
209905 OK OK OK OK OK OK OK OK X X X X X OK
209921/209925 OK OK OK OK OK OK OK OK X X OK X X OK
209903 OK* OK* OK* OK* OK* OK* OK* OK* OK X X X X OK*
209923 OK* OK* OK* OK* OK* OK* OK* OK* OK OK OK* OK ** OK*
209501 OK* OK* OK* OK* OK* OK* OK* OK* OK OK OK* OK ** OK*
Male connectors
209902 OK OK OK OK OK OK OK OK X X X X X OK
209961/209962 OK OK OK OK OK OK OK OK X X X X X OK
209904 OK* OK* OK* OK* OK* OK* OK* OK* OK X X X X OK*
209906 OK OK OK OK OK OK OK OK X X X X X OK
209965/209966 OK OK OK OK OK OK OK OK X X X X X OK
209922 OK* OK* OK* OK* OK* OK* OK* OK* X X OK X X OK*
209924 OK* OK* OK* OK* OK* OK* OK* OK* OK* OK OK* OK ** OK*

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility


TypeF/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.022
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diameterin0.045
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Shielding foil of pairsAluminium + Polyester
Outer sheath Diameterin0.283
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceΩ/100m < 9.38
Nominal speed%72
Operating temperature°F -13 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
2 3.7 5.2 5.8 7.3 8.2 9.2 10.3 14.6 18.6 26.5 29.8
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
88.9 78.7 77.7 71.7 69.3 71.1 65.8 63.9 58.6 54 48.7 45.8
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
86.7 76.3 75 69.8 67.2 69 63.7 61.4 56.5 52.8 46 42.6
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
87 75.1 72.7 66.2 62 62.9 56.7 53.8 44.1 35.4 22.2 16
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
84.7 72.7 70.1 64.2 60 60.9 54.6 51.2 42 34.3 19.6 13
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
81 70.4 67.2 66.9 63.7 59 55.1 53.5 49.3 43.9 40.5 35.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
79.2 67.8 63.8 63.2 61.6 57 52.9 50.5 46 43.5 37.5 34.8
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3
Return losses (typ.)dB
26.8 28.5 35.1 36.2 41.8 39.9 40.3 39.4 35.2 32 32.2 30.1

Physical data

Net weight: 54 g

Gross weight: 57 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 54 g

Packing

Reel 500 m

Pallet 13500 m

More Information
tlv_tags

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219910 212201   2123   212302 212305 212310 212101 219302 219312 219322 219102 212330
Female connectors 209901/209907 OK OK OK OK OK OK OK OK X X X X X OK
209905 OK OK OK OK OK OK OK OK X X X X X OK
209921/209925 OK OK OK OK OK OK OK OK X X OK X X OK
209903 OK* OK* OK* OK* OK* OK* OK* OK* OK X X X X OK*
209923 OK* OK* OK* OK* OK* OK* OK* OK* OK OK OK* OK ** OK*
209501 OK* OK* OK* OK* OK* OK* OK* OK* OK OK OK* OK ** OK*
Male connectors
209902 OK OK OK OK OK OK OK OK X X X X X OK
209961/209962 OK OK OK OK OK OK OK OK X X X X X OK
209904 OK* OK* OK* OK* OK* OK* OK* OK* OK X X X X OK*
209906 OK OK OK OK OK OK OK OK X X X X X OK
209965/209966 OK OK OK OK OK OK OK OK X X X X X OK
209922 OK* OK* OK* OK* OK* OK* OK* OK* X X OK X X OK*
209924 OK* OK* OK* OK* OK* OK* OK* OK* OK* OK OK* OK ** OK*

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

tlv_caracteristicas_ficha

El cable de tipo Cat-6 cumple el estándar de cables para Gigabit Ethernet y además es compatible hacia atrás, con los estándares de categorías inferiores (Cat-5/5e y Cat-3). La categoría 6 posee características y especificaciones para evitar la diafonía (o crosstalk) y el ruido. Alcanza frecuencias de transmisión de hasta 250 MHz (en cada par) y con una velocidad de 1 Gbps de transferencia. Este tipo de cable de datos se utiliza para instalaciones 10BASE-T, 100BASE-T y 1000BASE-T (Gigabit Ethernet).

Las características principales de los cables Televés Cat-6 son:

  • Cumplen TIA/EIA568B.2-1
  • Relleno tipo Crucifix
  • Posee hilo de rasgado para su fácil apertura
  • Impedancia de 100 ohmios
  • Resistencia máxima por conductor, menor a 117 ohmios/Km
tlv_reflog CAT6L500V
tlv_tabla_especificaciones
TypeF/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diameterin0.022
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diameterin0.045
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Shielding foil of pairsAluminium + Polyester
Outer sheath Diameterin0.283
Outer sheath MaterialLSFH
Outer sheath Thicknessin0.024
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceΩ/100m < 9.38
Nominal speed%72
Operating temperature°F -13 ... 158
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
2 3.7 5.2 5.8 7.3 8.2 9.2 10.3 14.6 18.6 26.5 29.8
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
88.9 78.7 77.7 71.7 69.3 71.1 65.8 63.9 58.6 54 48.7 45.8
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
86.7 76.3 75 69.8 67.2 69 63.7 61.4 56.5 52.8 46 42.6
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
87 75.1 72.7 66.2 62 62.9 56.7 53.8 44.1 35.4 22.2 16
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
84.7 72.7 70.1 64.2 60 60.9 54.6 51.2 42 34.3 19.6 13
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
81 70.4 67.2 66.9 63.7 59 55.1 53.5 49.3 43.9 40.5 35.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
79.2 67.8 63.8 63.2 61.6 57 52.9 50.5 46 43.5 37.5 34.8
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3
Return losses (typ.)dB
26.8 28.5 35.1 36.2 41.8 39.9 40.3 39.4 35.2 32 32.2 30.1
tlv_ean 8424450186510
tlv_dim_product_x 7
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 7
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 54
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 57
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 54
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 500
tlv_2_pcs_pack 13500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE DATA CABLE SECTION

  1. Inner conductor
  2. Inner conductor isolation
  3. Crucifix Filler
  4. Outer sheath
  5. Rip cord
  6. Shielding foil
  7. Drain wire