The wishlist name can't be left blank
SK110plus 18 VAtC coaxial cable Eca Euroclass, A+ Class shielded

SK110plus 18 VAtC coaxial cable Eca Euroclass, A+ Class shielded

SK125plus 18 VAtC coaxial cable Eca Euroclass, A+ Class shielded

RG-6 coaxial cable with both conductors made of copper (Cu/Cu) and outstanding braid coverage (60%). Triple shielded (TSH) cable, equipped with a second foil for extra shielded. An 18 VAtC cable with PVC sheath.

In stock
SKU
4135xx_coaxial_SK125
Select your product
Grouped product items
Ref. 413501 Reel type: Plastic reel, Length: 100 m
Ref. 413502 Reel type: Plastic reel, Length: 250 m
Ref. 413503 Reel type: Wooden drum, Length: 500 m
Generate PDF
Highlights
  • Copper conductors
  • Class A+ shielded
  • Eca Euroclass

Main features
  • White-colour external PVC sheath
  • 75 Ohm characteristic impedance
  • Available in reels of different lengths

Discover

Class A+ Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A+, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 2.5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 95 dB
  • For 1000 MHz - 2000 MHz => SA > 85 dB
  • For 2000 MHz - 3000 MHz => SA > 75 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

Class A+ Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A+, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 2.5 mΩ/m
  • For 5 MHz - 1000 MHz => SA > 95 dB
  • For 1000 MHz - 2000 MHz => SA > 85 dB
  • For 2000 MHz - 3000 MHz => SA > 75 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelSK125plus
Cable typeRG-6
StandardEN 50117-9-2
EuroclassEca
ClassA+
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 22
Dielectric Diametermm4.6
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorOrange RAL 1007
Overlapped foilAluminium + Polyester
Braid MaterialTinned copper (CuSn)
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)6
Braid Dimensions: strand diameter (Ø)mm0.115
Braid ResistanceΩ/km < 15
Braid Coverage%60
2nd foilYes
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.7
Outer sheath MaterialPVC
Minimum bending radiusmm33.5
Transfer impedance (5-30MHz)mΩ/m < 2.5
1GHz shieldingdB > 95
Spark TestVac3000
CapacitancepF/m53
ImpedanceΩ75
Velocity ratio%84
Operating temperature°C -30 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.02 0.05 0.05 0.06 0.09 0.14 0.16 0.18 0.19 0.2 0.21 0.22 0.25 0.28 0.31 0.32 0.32 0.32 0.34 0.36
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E-Second foil
F-Outer sheath